AE-800
AE-800 Features
Universal AC input / Full range
Programmable output voltage (0%~105%)
Programmable output current (0%~105%)
Forced current sharing at parallel operation
Constant current limit
Selectable +5V / 0.5A or +9V / 0.3A auxiliary output
Remote setting multiple PSU via RS-232, RS-485 & I2C
Power OK signal
Remote ON / OFF, Remote sense function
Protection: OVP, OLP, OTP, Fan failure
Accessory: CT Series
| MODEL | AE-800-12, AE-800-15, AE-800-24, AE-800-30, AE-800-36, AE-800-48, AE-800-60 |
|---|---|
| Main Features | ◎ Programmable output voltage and output current (0%~105%) ◎ Constant current limit suitable for battery charging application ◎ Parallel connection with current sharing ◎ Serial connection ( |
| Rated Power | 800W |
| DC Output Voltage | 12V; 15V; 24V; 30V; 36V; 48V; 60V |
| DC Output Quantity | Single |
| Rated Current | 66.7A; 53.4A; 33.5A; 26.7A; 22.3A; 16.7A; 13.4A |
| Ripple & Noise (Max.) | 120mVp-p; 150mVp-p; 240mVp-p; 300mVp-p; 360mVp-p; 480mVp-p; 600mVp-p |
| Input Voltage Range | 90~264VAC, 127~370VDC |
| Inrush Current (Typ.) | 30A / 115VAC, 60A / 230VAC |
| Function | Auxiliary power; Remote ON/OFF control; Power OK signal; Output voltage trim; Output current trim; Address setting |
| Parallel Connection | Yes |
| Protection | Over Load / Over Voltage / Over Temperature / Fan Failure |
| Cooling | Load and temperature control fan |
| Efficiency | 89%; 90%; 92%; 92%; 92%; 92%; 93% |
| Operating Temperature | -20~60℃ |
| Storage Temp. & Humidity | -40~85℃, 10~95%RH |
| Safety | TUV / UL / CE |
| Dimension (WxHxD) | 127x41x249 mm |
| Weight (Net) | 1.7kg |
Unit:mm [inch]